A review of correlations to model the packing structure and effective thermal conductivity in packed beds of mono-sized spherical particles W Van Antwerpen, CG Du Toit, PG Rousseau Nuclear Engineering and design 240 (7), 1803-1818, 2010 | 308 | 2010 |
Velocity measurements close to rippled beds in oscillatory flow CG Du Toit, JFA Sleath Journal of Fluid Mechanics 112, 71-96, 1981 | 138 | 1981 |
Velocity measurements close to rippled beds in oscillatory flow CG Du Toit, JFA Sleath Journal of Fluid Mechanics 112, 71-96, 1981 | 138 | 1981 |
Radial variation in porosity in annular packed beds CG Du Toit Nuclear engineering and design 238 (11), 3073-3079, 2008 | 122 | 2008 |
Multi-sphere Unit Cell model to calculate the effective thermal conductivity in packed pebble beds of mono-sized spheres W Van Antwerpen, PG Rousseau, CG Du Toit Nuclear Engineering and Design 247, 183-201, 2012 | 86 | 2012 |
Multi-sphere Unit Cell model to calculate the effective thermal conductivity in packed pebble beds of mono-sized spheres W Van Antwerpen, PG Rousseau, CG Du Toit Nuclear Engineering and Design 247, 183-201, 2012 | 86 | 2012 |
A systems CFD model of a packed bed high temperature gas-cooled nuclear reactor CG Du Toit, PG Rousseau, GP Greyvenstein, WA Landman International journal of thermal sciences 45 (1), 70-85, 2006 | 74 | 2006 |
A systems CFD model of a packed bed high temperature gas-cooled nuclear reactor CG Du Toit, PG Rousseau, GP Greyvenstein, WA Landman International journal of thermal sciences 45 (1), 70-85, 2006 | 74 | 2006 |
Separate effects tests to determine the effective thermal conductivity in the PBMR HTTU test facility PG Rousseau, CG Du Toit, W Van Antwerpen, HJ Van Antwerpen Nuclear Engineering and Design 271, 444-458, 2014 | 44 | 2014 |
Validation of a transient thermal-fluid systems CFD model for a packed bed high temperature gas-cooled nuclear reactor PG Rousseau, CG Du Toit, WA Landman Nuclear engineering and design 236 (5-6), 555-564, 2006 | 43 | 2006 |
The numerical determination of the variation in the porosity of the pebble-bed core CG Du Toit | 31 | 2002 |
Modeling the flow and heat transfer in a packed bed high temperature gas-cooled reactor in the context of a systems CFD approach CG Du Toit, PG Rousseau Journal of heat transfer 134 (3), 2012 | 25 | 2012 |
A methodology to investigate the contribution of conduction and radiation heat transfer to the effective thermal conductivity of packed graphite pebble beds, including the wall … M De Beer, CG Du Toit, PG Rousseau Nuclear Engineering and Design 314, 67-81, 2017 | 23 | 2017 |
Finite element solution of the Navier-Stokes equations for incompressible flow using a segregated algorithm CG Du Toit Computer methods in applied mechanics and engineering 151 (1-2), 131-141, 1998 | 23 | 1998 |
Performance modelling of a parallel tube polymer absorber WMK Van Niekerk, CG Du Toit, TB Scheffler Solar Energy 58 (1-3), 39-44, 1996 | 22 | 1996 |
Analysis of the porous structure of an annular pebble bed reactor CG Du Toit, W Van Antwerpen, PG Rousseau Atomic Energy Society of Japan, 2009 | 18 | 2009 |
Accounting for porous structure in effective thermal conductivity calculations in a pebble bed reactor W Van Antwerpen, PG Rousseau, CG Du Toit Atomic Energy Society of Japan, 2009 | 14 | 2009 |
Modelling of the recirculation in mechanical-draught heat exchangers CG Du Toit, DG Kroger R&D Journal 9 (1), 2-8, 1993 | 14 | 1993 |
Air-cooled steam condenser performance in the presence of crosswinds HB Goldschagg, F Vogt, CG du Toit, GD Thiart, DG Kröger Proceedings: Cooling Tower Technology Conference, Electrical Power Research …, 1997 | 13 | 1997 |
A review of methods to predict the effective thermal conductivity of packed pebble beds, with emphasis on the near-wall region M De Beer, PG Rousseau, CG Du Toit Nuclear Engineering and Design 331, 248-262, 2018 | 12 | 2018 |