Acute pulmonary vein isolation is achieved by a combination of reversible and irreversible atrial injury after catheter ablation: evidence from magnetic resonance imaging A Arujuna, R Karim, D Caulfield, B Knowles, K Rhode, T Schaeffter, ... Circulation: Arrhythmia and Electrophysiology 5 (4), 691-700, 2012 | 159 | 2012 |
Registration of 3D trans-esophageal echocardiography to X-ray fluoroscopy using image-based probe tracking G Gao, G Penney, Y Ma, N Gogin, P Cathier, A Arujuna, G Morton, ... Medical image analysis 16 (1), 38-49, 2012 | 131 | 2012 |
Personalization of atrial anatomy and electrophysiology as a basis for clinical modeling of radio-frequency ablation of atrial fibrillation MW Krueger, G Seemann, K Rhode, DUJ Keller, C Schilling, A Arujuna, ... IEEE transactions on medical imaging 32 (1), 73-84, 2012 | 108 | 2012 |
Quantitative magnetic resonance imaging analysis of the relationship between contact force and left atrial scar formation after catheter ablation of atrial fibrillation C Sohns, R Karim, J Harrison, A Arujuna, N Linton, R Sennett, H Lambert, ... Journal of cardiovascular electrophysiology 25 (2), 138-145, 2014 | 74 | 2014 |
Pacemaker and defibrillator lead extraction: predictors of mortality during follow‐up S Hamid, A Arujuna, M Ginks, M McPHAIL, N Patel, C Bucknall, C Rinaldi Pacing and clinical electrophysiology 33 (2), 209-216, 2010 | 72 | 2010 |
Trends, indications and outcomes of cardiac implantable device system extraction: a single UK centre experience over the last decade A Arujuna, S Williams, J Whittaker, A Shetty, D Roy, J Bostock, ... International journal of clinical practice 66 (2), 218-225, 2012 | 49 | 2012 |
Evaluation of a real-time hybrid three-dimensional echo and X-ray imaging system for guidance of cardiac catheterisation procedures RJ Housden, A Arujuna, Y Ma, N Nijhof, G Gijsbers, R Bullens, M O’Neill, ... Medical Image Computing and Computer-Assisted Intervention–MICCAI 2012: 15th …, 2012 | 43 | 2012 |
Percutaneous lead and system extraction in patients with cardiac resynchronization therapy (CRT) devices and coronary sinus leads SE Williams, A Arujuna, J Whitaker, AK Shetty, J Bostock, N Patel, ... Pacing and clinical electrophysiology 34 (10), 1209-1216, 2011 | 43 | 2011 |
Radial Versus Femoral Access Is Associated With Reduced Complications and Mortality in Patients With Non–ST-Segment–Elevation Myocardial Infarction: An Observational Cohort … MB Iqbal, A Arujuna, C Ilsley, A Archbold, T Crake, S Firoozi, S Kalra, ... Circulation: Cardiovascular Interventions 7 (4), 456-464, 2014 | 41 | 2014 |
A method to standardize quantification of left atrial scar from delayed-enhancement MR images R Karim, A Arujuna, RJ Housden, J Gill, H Cliffe, K Matharu, J Gill, ... IEEE journal of translational engineering in health and medicine 2, 1-15, 2014 | 38 | 2014 |
Rapid image registration of three-dimensional transesophageal echocardiography and X-ray fluoroscopy for the guidance of cardiac interventions G Gao, G Penney, N Gogin, P Cathier, A Arujuna, M Wright, D Caulfield, ... Information Processing in Computer-Assisted Interventions: First …, 2010 | 27 | 2010 |
Novel system for real-time integration of 3-D echocardiography and fluoroscopy for image-guided cardiac interventions: preclinical validation and clinical feasibility evaluation AV Arujuna, RJ Housden, Y Ma, R Rajani, G Gao, N Nijhof, P Cathier, ... IEEE Journal of Translational Engineering in Health and Medicine 2, 1-10, 2014 | 26 | 2014 |
Extended-field-of-view three-dimensional transesophageal echocardiography using image-based X-ray probe tracking RJ Housden, YL Ma, A Arujuna, N Nijhof, P Cathier, G Gijsbers, R Bullens, ... Ultrasound in medicine & biology 39 (6), 993-1005, 2013 | 25 | 2013 |
The current practice and perception of cardiac implantable electronic device transvenous lead extraction in the UK M Sohal, SE Williams, A Arujuna, Z Chen, J Bostock, JS Gill, CA Rinaldi Europace 15 (6), 865-870, 2013 | 24 | 2013 |
Automatic segmentation of left atrial scar from delayed-enhancement magnetic resonance imaging R Karim, A Arujuna, A Brazier, J Gill, CA Rinaldi, M O’Neill, R Razavi, ... Functional Imaging and Modeling of the Heart: 6th International Conference …, 2011 | 23 | 2011 |
Effects of tracer arrival time on the accuracy of high-resolution (voxel-wise) myocardial perfusion maps from contrast-enhanced first-pass perfusion magnetic resonance N Zarinabad, GLTF Hautvast, E Sammut, A Arujuna, M Breeuwer, E Nagel, ... IEEE Transactions on Biomedical Engineering 61 (9), 2499-2506, 2014 | 22 | 2014 |
Percutaneous extraction of cardiac implantable electronic devices (CIEDs) in octogenarians SE Williams, A Arujuna, J Whitaker, M Sohal, AK Shetty, D Roy, J Bostock, ... Pacing and clinical electrophysiology 35 (7), 841-849, 2012 | 21 | 2012 |
Male gender and chronic obstructive pulmonary disease predict a poor clinical response in patients undergoing cardiac resynchronisation therapy S Kirubakaran, A Ladwiniec, A Arujuna, M Ginks, M McPhail, J Bostock, ... International Journal of Clinical Practice 65 (3), 281-288, 2011 | 20 | 2011 |
London Heart Attack Centre (HAC) Group Investigators MB Iqbal, A Arujuna, C Ilsley, A Archbold, T Crake, S Firoozi, S Kalra, ... Culprit vessel versus multivessel intervention at the time of primary …, 0 | 17 | |
Lower incidence of inappropriate shock therapy in patients with combined cardiac resynchronisation therapy defibrillators (CRT‐D) compared with patients with non‐CRT … Z Chen, T Kotecha, S Crichton, A Shetty, M Sohal, A Arujuna, ... International Journal of Clinical Practice 67 (8), 733-739, 2013 | 16 | 2013 |