Power signature analysis C Laughman, K Lee, R Cox, S Shaw, S Leeb, L Norford, P Armstrong IEEE power and energy magazine 1 (2), 56-63, 2003 | 784 | 2003 |
Conceptual design study for heat exhaust management in the ARC fusion pilot plant AQ Kuang, NM Cao, AJ Creely, CA Dennett, J Hecla, B LaBombard, ... Fusion Engineering and Design 137, 221-242, 2018 | 102 | 2018 |
Modelingtoolkit: A composable graph transformation system for equation-based modeling Y Ma, S Gowda, R Anantharaman, C Laughman, V Shah, C Rackauckas arXiv preprint arXiv:2103.05244, 2021 | 101 | 2021 |
Detection of rooftop cooling unit faults based on electrical measurements PR Armstrong, CR Laughman, SB Leeb, LK Norford HVAC&R Research 12 (1), 151-175, 2006 | 80 | 2006 |
A Kalman-filter spectral envelope preprocessor SR Shaw, CR Laughman IEEE Transactions on Instrumentation and Measurement 56 (5), 2010-2017, 2007 | 63 | 2007 |
HVAC control system D Nikovski, C Laughman US Patent 8,412,381, 2013 | 62 | 2013 |
Extremum seeking control for energy optimization of vapor compression systems D Burns, C Laughman | 59 | 2012 |
Diagnostic indicators for shipboard systems using non-intrusive load monitoring T DeNucci, R Cox, SB Leeb, J Paris, TJ McCoy, C Laughman, WC Greene IEEE Electric Ship Technologies Symposium, 2005., 413-420, 2005 | 56 | 2005 |
Optimization of circuitry arrangements for heat exchangers using derivative-free optimization N Ploskas, C Laughman, AU Raghunathan, NV Sahinidis Chemical Engineering Research and Design 131, 16-28, 2018 | 45 | 2018 |
An advanced switching moving boundary heat exchanger model with pressure drop H Qiao, CR Laughman, V Aute, R Radermacher International journal of refrigeration 65, 154-171, 2016 | 45 | 2016 |
A power quality prediction system SR Shaw, CR Laughman, SB Leeb, RF Lepard IEEE Transactions on Industrial Electronics 47 (3), 511-517, 2000 | 43 | 2000 |
Scalable Bayesian optimization for model calibration: Case study on coupled building and HVAC dynamics A Chakrabarty, E Maddalena, H Qiao, C Laughman Energy and Buildings 253, 111460, 2021 | 42 | 2021 |
Advanced nonintrusive monitoring of electric loads C Laughman, D Lee, R Cox, S Shaw, S Leeb, L Norford, P Armstrong IEEE Power and Energy Magazine, 56-63, 2003 | 40 | 2003 |
Accelerating self-optimization control of refrigerant cycles with Bayesian optimization and adaptive moment estimation A Chakrabarty, C Danielson, SA Bortoff, CR Laughman Applied Thermal Engineering 197, 117335, 2021 | 35 | 2021 |
Method for reconstructing 3D scenes from 2D images S Ramalingam, Y Taguchi, JK Pillai, DJ Burns, CR Laughman US Patent 9,595,134, 2017 | 33 | 2017 |
Accelerating simulation of stiff nonlinear systems using continuous-time echo state networks R Anantharaman, Y Ma, S Gowda, C Laughman, V Shah, A Edelman, ... arXiv preprint arXiv:2010.04004, 2020 | 32 | 2020 |
Calibrating building simulation models using multi-source datasets and meta-learned Bayesian optimization S Zhan, G Wichern, C Laughman, A Chong, A Chakrabarty Energy and Buildings 270, 112278, 2022 | 30 | 2022 |
VABO: Violation-aware Bayesian optimization for closed-loop control performance optimization with unmodeled constraints W Xu, CN Jones, B Svetozarevic, CR Laughman, A Chakrabarty 2022 American Control Conference (ACC), 5288-5293, 2022 | 28 | 2022 |
A comparison of transient heat pump cycle models using alternative flow descriptions CR Laughman, H Qiao, V Aute, R Radermacher Science and Technology for the Built Environment 21 (5), 666-680, 2015 | 28 | 2015 |
Fault detection and diagnostics for non-intrusive monitoring using motor harmonics UA Orji, Z Remscrim, C Laughman, SB Leeb, W Wichakool, C Schantz, ... 2010 twenty-fifth annual IEEE applied power electronics conference and …, 2010 | 28 | 2010 |